Author Affiliations
Abstract
State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
A novel fiber inline Mach-Zehnder interferometer (MZI) is proposed for simultaneous measurement of curvature and temperature. The sensor composes of single mode-multimode-dispersion compensation-multimode-single mode fiber (MMF-DCF-MMF) structure, using the direct fusion technology. The experimental results show curvature sensitivities of -12.82 nm/m-1 and -14.42 nm/m-1 in the range of 0 - 0.65 m-1 for two resonant dips, as well as temperature sensitivities of 57.6 pm/℃ and 74.3 pm/℃ within the range of 20 ℃ - 150 ℃. In addition, the sensor has unique advantages of easy fabrication, low cost, high fringe visibility of 24 dB, and high sensitivity, which shows a good application prospect in dual-parameters of sensing of curvature and temperature.
Mach-Zehnder interferometer curvature sensing temperature sensing simultaneous sensing 
Photonic Sensors
2020, 10(2): 171
Author Affiliations
Abstract
State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
A high sensitive refractive index sensor based on the cladding etched photonic crystal fiber (PCF) Mach-Zehnder interferometer (MZI) is proposed, which is spliced a section of photonic crystal fiber between two single modes fibers (SMFs).The interference fringe of the MZI shifts with the variation of the ambient refractive index (RI). It is found that the RI sensitivity slightly decrease with an increase in the interference length. The sensitivities of MZI with 35mm PCF, 40mm PCF, and 45mm PCF are 106.19nm/RIU, 93.33nm/RIU, and 73.64nm/RIU, respectively, in the range of 1.333 to 1.381. After etched, the RI sensitivity of the MZI could be improved obviously. The RI sensitivities of the MZI with 35mm PCF are up to 211.53nm/RIU and 359.37nm/RIU when the cladding diameter decreases to 112μm and 91μm, respectively. Moreover, the sensor is insensitive to temperature, and the measured sensitivity is only 9.21pm/℃ with the range from 20℃ to 500℃. In addition, the sensor has advantage of simple fabrication, low cost, and high RI sensitivity.
Refractive index sensor Mach-Zehnder interferometer photonic crystal fiber hydrofluoric acid 
Photonic Sensors
2019, 9(2): 02126

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!